{"product_id":"idc12-1048aj-48-ambient-air-240v-single-phase-industrial-direct-drive-12-series","title":"IDC12-1048AJ - 48\", Ambient Air, 240V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1042AJ - 48\", Ambient, 240V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eFor wall and top mounting at heights up to 12′ (environmental separation) and 10′ (insect control). The Berner Industrial Direct Drive 12 Ambient Air Curtain is AMCA certified, measures 15″ high by 18″ deep, with all-welded construction, a gray powder-coated exterior, and mill aluminum inlet panel. Used to save energy and keep temperatures stable, and flying insects out when the doors are open. Recommended for shipping and receiving doors, garage doors, cold storage doors, baggage doors, etc. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cfda1a1f2-24-single-phase-control-panel-nema-4-12-enclosure-120v-for-4-motor-idc12-14-units\"\u003e9012CFDA1A1F2-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48166590021873,"sku":"IDC12-1048AJ","price":2183.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153","url":"https:\/\/aircurtainsdirect.com\/en-us\/products\/idc12-1048aj-48-ambient-air-240v-single-phase-industrial-direct-drive-12-series","provider":"AirCurtainsDirect.com","version":"1.0","type":"link"}