{"title":"Air Curtains - Berner IDC12 - Industrial Direct 12 Series","description":"","products":[{"product_id":"idc12-1036aa-36-ambient-air-120v-single-phase-industrial-direct-drive-12-series","title":"IDC12-1036AA - 36\", Ambient Air, 120V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1036AA - 36\", Ambient, 120V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1036AA delivers 1,512 CFM of unheated air through a 36\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 120V single phase, drawing 0.51 kW. Built for door openings up to 36\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 100 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p120-24-single-phase-control-panel-nema-4-12-enclosure-120v-1-to-3-motors\"\u003e9012CS40A3P120-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":47191308632305,"sku":"IDC12-1036AA","price":2450.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-3096aa-96-ambient-air-120v-single-phase-industrial-direct-drive-12-series","title":"IDC12-3096AA - 96\", Ambient Air, 120V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-3096AA - 96\", Ambient, 120V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-3096AA delivers 4,443 CFM of unheated air through a 99\" Pro-V nozzle, powered by 3 × ½ HP single-speed direct-drive motors at 120V single phase, drawing 1.50 kW. Built for door openings up to 96\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 240 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p120-24-single-phase-control-panel-nema-4-12-enclosure-120v-1-to-3-motors\"\u003e9012CS40A3P120-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48038382141681,"sku":"IDC12-3096AA","price":6550.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1042aj-42-ambient-air-240v-single-phase-industrial-direct-drive-12-series","title":"IDC12-1042AJ - 42\", Ambient Air, 240V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1042AJ - 42\", Ambient, 240V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1042AJ delivers 1,583 CFM of unheated air through a 42\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 240V single phase, drawing 0.52 kW. Built for door openings up to 42\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 106 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48083494764785,"sku":"IDC12-1042AJ","price":2475.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-3120aa-120-ambient-air-120v-single-phase-industrial-direct-drive-12-series","title":"IDC12-3120AA - 120\", Ambient Air, 120V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-3120AA - 120\", Ambient, 120V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-3120AA delivers 4,678 CFM of unheated air through a 117\" Pro-V nozzle, powered by 3 × ½ HP single-speed direct-drive motors at 120V single phase, drawing 1.55 kW. Built for door openings up to 120\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 290 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p120-24-single-phase-control-panel-nema-4-12-enclosure-120v-1-to-3-motors\"\u003e9012CS40A3P120-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48102541656305,"sku":"IDC12-3120AA","price":7400.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1048aj-48-ambient-air-240v-single-phase-industrial-direct-drive-12-series","title":"IDC12-1048AJ - 48\", Ambient Air, 240V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1048AJ - 48\", Ambient, 240V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1048AJ delivers 1,594 CFM of unheated air through a 48\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 240V single phase, drawing 0.53 kW. Built for door openings up to 48\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 111 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48166590021873,"sku":"IDC12-1048AJ","price":2500.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1060aj-60-ambient-air-240v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2060AJ - 60\", Ambient Air, 240V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2060AJ - 60\", Ambient, 240V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2060AJ delivers 2,931 CFM of unheated air through a 66\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 240V single phase, drawing 0.99 kW. Built for door openings up to 60\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 169 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48166600474865,"sku":"IDC12-2060AJ","price":4025.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-3096aj-96-ambient-air-240v-single-phase-industrial-direct-drive-12-series","title":"IDC12-3096AJ - 96\", Ambient Air, 240V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-3096AJ - 96\", Ambient, 240V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-3096AJ delivers 4,443 CFM of unheated air through a 99\" Pro-V nozzle, powered by 3 × ½ HP single-speed direct-drive motors at 240V single phase, drawing 1.50 kW. Built for door openings up to 96\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 240 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48166602047729,"sku":"IDC12-3096AJ","price":6550.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-3120aj-120-ambient-air-240v-single-phase-industrial-direct-drive-12-series","title":"IDC12-3120AJ - 120\", Ambient Air, 240V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-3120AJ - 120\", Ambient, 240V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-3120AJ delivers 4,678 CFM of unheated air through a 117\" Pro-V nozzle, powered by 3 × ½ HP single-speed direct-drive motors at 240V single phase, drawing 1.55 kW. Built for door openings up to 120\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 290 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48166603915505,"sku":"IDC12-3120AJ","price":7400.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1036ab-36-ambient-air-208v-single-phase-industrial-direct-drive-12-series","title":"IDC12-1036AB - 36\", Ambient Air, 208V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1036AB - 36\", Ambient, 208V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1036AB delivers 1,512 CFM of unheated air through a 36\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 208V single phase, drawing 0.51 kW. Built for door openings up to 36\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 100 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171974754545,"sku":"IDC12-1036AB","price":2450.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1036aj-36-ambient-air-240v-single-phase-industrial-direct-drive-12-series","title":"IDC12-1036AJ - 36\", Ambient Air, 240V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1036AJ - 36\", Ambient, 240V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1036AJ delivers 1,512 CFM of unheated air through a 36\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 240V single phase, drawing 0.51 kW. Built for door openings up to 36\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 100 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171974787313,"sku":"IDC12-1036AJ","price":2450.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1036ax-36-ambient-air-208v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1036AX - 36\", Ambient Air, 208V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1036AX - 36\", Ambient, 208V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1036AX delivers 1,512 CFM of unheated air through a 36\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 208V three phase, drawing 0.51 kW. Built for door openings up to 36\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 100 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171974820081,"sku":"IDC12-1036AX","price":2450.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1036ay-36-ambient-air-240v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1036AY - 36\", Ambient Air, 240V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1036AY - 36\", Ambient, 240V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1036AY delivers 1,512 CFM of unheated air through a 36\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 240V three phase, drawing 0.51 kW. Built for door openings up to 36\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 100 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171974852849,"sku":"IDC12-1036AY","price":2450.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1036az-36-ambient-air-480v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1036AZ - 36\", Ambient Air, 480V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1036AZ - 36\", Ambient, 480V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1036AZ delivers 1,512 CFM of unheated air through a 36\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 480V three phase, drawing 0.51 kW. Built for door openings up to 36\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 100 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171974885617,"sku":"IDC12-1036AZ","price":2450.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1036aq-36-ambient-air-600v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1036AQ - 36\", Ambient Air, 600V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1036AQ - 36\", Ambient, 600V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1036AQ delivers 1,512 CFM of unheated air through a 36\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 600V three phase, drawing 0.51 kW. Built for door openings up to 36\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 100 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171974918385,"sku":"IDC12-1036AQ","price":2450.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1042aa-42-ambient-air-120v-single-phase-industrial-direct-drive-12-series","title":"IDC12-1042AA - 42\", Ambient Air, 120V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1042AA - 42\", Ambient, 120V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1042AA delivers 1,583 CFM of unheated air through a 42\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 120V single phase, drawing 0.52 kW. Built for door openings up to 42\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 106 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p120-24-single-phase-control-panel-nema-4-12-enclosure-120v-1-to-3-motors\"\u003e9012CS40A3P120-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171978162417,"sku":"IDC12-1042AA","price":2475.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1042ab-42-ambient-air-208v-single-phase-industrial-direct-drive-12-series","title":"IDC12-1042AB - 42\", Ambient Air, 208V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1042AB - 42\", Ambient, 208V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1042AB delivers 1,583 CFM of unheated air through a 42\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 208V single phase, drawing 0.52 kW. Built for door openings up to 42\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 106 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171978227953,"sku":"IDC12-1042AB","price":2475.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1042ax-42-ambient-air-208v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1042AX - 42\", Ambient Air, 208V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1042AX - 42\", Ambient, 208V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1042AX delivers 1,583 CFM of unheated air through a 42\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 208V three phase, drawing 0.52 kW. Built for door openings up to 42\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 106 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171978424561,"sku":"IDC12-1042AX","price":2475.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1042ay-42-ambient-air-240v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1042AY - 42\", Ambient Air, 240V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1042AY - 42\", Ambient, 240V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1042AY delivers 1,583 CFM of unheated air through a 42\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 240V three phase, drawing 0.52 kW. Built for door openings up to 42\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 106 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171978457329,"sku":"IDC12-1042AY","price":2475.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1042az-42-ambient-air-480v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1042AZ - 42\", Ambient Air, 480V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1042AZ - 42\", Ambient, 480V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1042AZ delivers 1,583 CFM of unheated air through a 42\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 480V three phase, drawing 0.52 kW. Built for door openings up to 42\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 106 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171978522865,"sku":"IDC12-1042AZ","price":2475.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1042aq-42-ambient-air-600v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1042AQ - 42\", Ambient Air, 600V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1042AQ - 42\", Ambient, 600V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1042AQ delivers 1,583 CFM of unheated air through a 42\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 600V three phase, drawing 0.52 kW. Built for door openings up to 42\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 106 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171978621169,"sku":"IDC12-1042AQ","price":2475.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1048aa-48-ambient-air-120v-single-phase-industrial-direct-drive-12-series","title":"IDC12-1048AA - 48\", Ambient Air, 120V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1048AA - 48\", Ambient, 120V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1048AA delivers 1,594 CFM of unheated air through a 48\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 120V single phase, drawing 0.53 kW. Built for door openings up to 48\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 111 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p120-24-single-phase-control-panel-nema-4-12-enclosure-120v-1-to-3-motors\"\u003e9012CS40A3P120-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171980226801,"sku":"IDC12-1048AA","price":2500.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1048ab-48-ambient-air-208v-single-phase-industrial-direct-drive-12-series","title":"IDC12-1048AB - 48\", Ambient Air, 208V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1048AB - 48\", Ambient, 208V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1048AB delivers 1,594 CFM of unheated air through a 48\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 208V single phase, drawing 0.53 kW. Built for door openings up to 48\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 111 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171980325105,"sku":"IDC12-1048AB","price":2500.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1048ax-48-ambient-air-208v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1048AX - 48\", Ambient Air, 208V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1048AX - 48\", Ambient, 208V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1048AX delivers 1,594 CFM of unheated air through a 48\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 208V three phase, drawing 0.53 kW. Built for door openings up to 48\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 111 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171980521713,"sku":"IDC12-1048AX","price":2500.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1048ay-48-ambient-air-240v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1048AY - 48\", Ambient Air, 240V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1048AY - 48\", Ambient, 240V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1048AY delivers 1,594 CFM of unheated air through a 48\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 240V three phase, drawing 0.53 kW. Built for door openings up to 48\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 111 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171980685553,"sku":"IDC12-1048AY","price":2500.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1048az-48-ambient-air-480v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1048AZ - 48\", Ambient Air, 480V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1048AZ - 48\", Ambient, 480V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1048AZ delivers 1,594 CFM of unheated air through a 48\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 480V three phase, drawing 0.53 kW. Built for door openings up to 48\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 111 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171980751089,"sku":"IDC12-1048AZ","price":2500.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-1048aq-48-ambient-air-600v-three-phase-industrial-direct-drive-12-series","title":"IDC12-1048AQ - 48\", Ambient Air, 600V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-1048AQ - 48\", Ambient, 600V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-1048AQ delivers 1,594 CFM of unheated air through a 48\" Pro-V nozzle, powered by 1 × ½ HP single-speed direct-drive motor at 600V three phase, drawing 0.53 kW. Built for door openings up to 48\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 111 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171981340913,"sku":"IDC12-1048AQ","price":2500.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2060aa-60-ambient-air-120v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2060AA - 60\", Ambient Air, 120V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2060AA - 60\", Ambient, 120V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2060AA delivers 2,931 CFM of unheated air through a 66\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 120V single phase, drawing 0.99 kW. Built for door openings up to 60\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 169 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p120-24-single-phase-control-panel-nema-4-12-enclosure-120v-1-to-3-motors\"\u003e9012CS40A3P120-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171981373681,"sku":"IDC12-2060AA","price":4025.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2060ab-60-ambient-air-208v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2060AB - 60\", Ambient Air, 208V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2060AB - 60\", Ambient, 208V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2060AB delivers 2,931 CFM of unheated air through a 66\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 208V single phase, drawing 0.99 kW. Built for door openings up to 60\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 169 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171981406449,"sku":"IDC12-2060AB","price":4025.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2060ax-60-ambient-air-208v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2060AX - 60\", Ambient Air, 208V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2060AX - 60\", Ambient, 208V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2060AX delivers 2,931 CFM of unheated air through a 66\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 208V three phase, drawing 0.99 kW. Built for door openings up to 60\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 169 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171981701361,"sku":"IDC12-2060AX","price":4025.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2060ay-60-ambient-air-240v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2060AY - 60\", Ambient Air, 240V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2060AY - 60\", Ambient, 240V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2060AY delivers 2,931 CFM of unheated air through a 66\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 240V three phase, drawing 0.99 kW. Built for door openings up to 60\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 169 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171981734129,"sku":"IDC12-2060AY","price":4025.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2060az-60-ambient-air-480v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2060AZ - 60\", Ambient Air, 480V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2060AZ - 60\", Ambient, 480V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2060AZ delivers 2,931 CFM of unheated air through a 66\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 480V three phase, drawing 0.99 kW. Built for door openings up to 60\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 169 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171981799665,"sku":"IDC12-2060AZ","price":4025.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2060aq-60-ambient-air-600v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2060AQ - 60\", Ambient Air, 600V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2060AQ - 60\", Ambient, 600V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2060AQ delivers 2,931 CFM of unheated air through a 66\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 600V three phase, drawing 0.99 kW. Built for door openings up to 60\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 169 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171982127345,"sku":"IDC12-2060AQ","price":4025.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2072aa-72-ambient-air-120v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2072AA - 72\", Ambient Air, 120V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2072AA - 72\", Ambient, 120V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2072AA delivers 3,024 CFM of unheated air through a 72\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 120V single phase, drawing 1.02 kW. Built for door openings up to 72\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 178 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p120-24-single-phase-control-panel-nema-4-12-enclosure-120v-1-to-3-motors\"\u003e9012CS40A3P120-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171982160113,"sku":"IDC12-2072AA","price":4150.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2072ab-72-ambient-air-208v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2072AB - 72\", Ambient Air, 208V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2072AB - 72\", Ambient, 208V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2072AB delivers 3,024 CFM of unheated air through a 72\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 208V single phase, drawing 1.02 kW. Built for door openings up to 72\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 178 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171982225649,"sku":"IDC12-2072AB","price":4150.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2072aj-72-ambient-air-240v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2072AJ - 72\", Ambient Air, 240V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2072AJ - 72\", Ambient, 240V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2072AJ delivers 3,024 CFM of unheated air through a 72\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 240V single phase, drawing 1.02 kW. Built for door openings up to 72\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 178 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171982258417,"sku":"IDC12-2072AJ","price":4150.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2072ax-72-ambient-air-208v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2072AX - 72\", Ambient Air, 208V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2072AX - 72\", Ambient, 208V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2072AX delivers 3,024 CFM of unheated air through a 72\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 208V three phase, drawing 1.02 kW. Built for door openings up to 72\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 178 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171982422257,"sku":"IDC12-2072AX","price":4150.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2072ay-72-ambient-air-240v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2072AY - 72\", Ambient Air, 240V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2072AY - 72\", Ambient, 240V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2072AY delivers 3,024 CFM of unheated air through a 72\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 240V three phase, drawing 1.02 kW. Built for door openings up to 72\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 178 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171982487793,"sku":"IDC12-2072AY","price":4150.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2072az-72-ambient-air-480v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2072AZ - 72\", Ambient Air, 480V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2072AZ - 72\", Ambient, 480V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2072AZ delivers 3,024 CFM of unheated air through a 72\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 480V three phase, drawing 1.02 kW. Built for door openings up to 72\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 178 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171982618865,"sku":"IDC12-2072AZ","price":4150.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2072aq-72-ambient-air-600v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2072AQ - 72\", Ambient Air, 600V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2072AQ - 72\", Ambient, 600V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2072AQ delivers 3,024 CFM of unheated air through a 72\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 600V three phase, drawing 1.02 kW. Built for door openings up to 72\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 178 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171982684401,"sku":"IDC12-2072AQ","price":4150.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2078aa-78-ambient-air-120v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2078AA - 78\", Ambient Air, 120V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2078AA - 78\", Ambient, 120V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2078AA delivers 3,095 CFM of unheated air through a 78\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 120V single phase, drawing 1.03 kW. Built for door openings up to 78\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 184 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p120-24-single-phase-control-panel-nema-4-12-enclosure-120v-1-to-3-motors\"\u003e9012CS40A3P120-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171983175921,"sku":"IDC12-2078AA","price":4575.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2078ab-78-ambient-air-208v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2078AB - 78\", Ambient Air, 208V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2078AB - 78\", Ambient, 208V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2078AB delivers 3,095 CFM of unheated air through a 78\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 208V single phase, drawing 1.03 kW. Built for door openings up to 78\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 184 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171983208689,"sku":"IDC12-2078AB","price":4575.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2078aj-78-ambient-air-240v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2078AJ - 78\", Ambient Air, 240V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2078AJ - 78\", Ambient, 240V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2078AJ delivers 3,095 CFM of unheated air through a 78\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 240V single phase, drawing 1.03 kW. Built for door openings up to 78\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 184 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171983241457,"sku":"IDC12-2078AJ","price":4575.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2078ax-78-ambient-air-208v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2078AX - 78\", Ambient Air, 208V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2078AX - 78\", Ambient, 208V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2078AX delivers 3,095 CFM of unheated air through a 78\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 208V three phase, drawing 1.03 kW. Built for door openings up to 78\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 184 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171983306993,"sku":"IDC12-2078AX","price":4575.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2078ay-78-ambient-air-240v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2078AY - 78\", Ambient Air, 240V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2078AY - 78\", Ambient, 240V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2078AY delivers 3,095 CFM of unheated air through a 78\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 240V three phase, drawing 1.03 kW. Built for door openings up to 78\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 184 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171983962353,"sku":"IDC12-2078AY","price":4575.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2078az-78-ambient-air-480v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2078AZ - 78\", Ambient Air, 480V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2078AZ - 78\", Ambient, 480V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2078AZ delivers 3,095 CFM of unheated air through a 78\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 480V three phase, drawing 1.03 kW. Built for door openings up to 78\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 184 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171983995121,"sku":"IDC12-2078AZ","price":4575.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2078aq-78-ambient-air-600v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2078AQ - 78\", Ambient Air, 600V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2078AQ - 78\", Ambient, 600V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2078AQ delivers 3,095 CFM of unheated air through a 78\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 600V three phase, drawing 1.03 kW. Built for door openings up to 78\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 184 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171984027889,"sku":"IDC12-2078AQ","price":4575.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2084aa-84-ambient-air-120v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2084AA - 84\", Ambient Air, 120V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2084AA - 84\", Ambient, 120V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2084AA delivers 3,166 CFM of unheated air through a 84\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 120V single phase, drawing 1.04 kW. Built for door openings up to 84\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 189 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p120-24-single-phase-control-panel-nema-4-12-enclosure-120v-1-to-3-motors\"\u003e9012CS40A3P120-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171984257265,"sku":"IDC12-2084AA","price":4700.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2084ab-84-ambient-air-208v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2084AB - 84\", Ambient Air, 208V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2084AB - 84\", Ambient, 208V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2084AB delivers 3,166 CFM of unheated air through a 84\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 208V single phase, drawing 1.04 kW. Built for door openings up to 84\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 189 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171984388337,"sku":"IDC12-2084AB","price":4700.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2084aj-84-ambient-air-240v-single-phase-industrial-direct-drive-12-series","title":"IDC12-2084AJ - 84\", Ambient Air, 240V, Single Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2084AJ - 84\", Ambient, 240V, Single Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2084AJ delivers 3,166 CFM of unheated air through a 84\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 240V single phase, drawing 1.04 kW. Built for door openings up to 84\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 189 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel \u003c\/strong\u003eand activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171984421105,"sku":"IDC12-2084AJ","price":4700.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"},{"product_id":"idc12-2084ax-84-ambient-air-208v-three-phase-industrial-direct-drive-12-series","title":"IDC12-2084AX - 84\", Ambient Air, 208V, Three Phase, Industrial Direct Drive 12 Series","description":"\u003ch4 class=\"js-requestQuoteModel\" style=\"text-align: left;\"\u003eIDC12-2084AX - 84\", Ambient, 208V, Three Phase\u003c\/h4\u003e\n\u003cp\u003eThe Berner IDC12-2084AX delivers 3,166 CFM of unheated air through a 84\" Pro-V nozzle, powered by 2 × ½ HP single-speed direct-drive motors at 208V three phase, drawing 1.04 kW. Built for door openings up to 84\" wide and mounting heights up to 12′ (environmental separation) or 10′ (insect control). AMCA certified, FDA recommended, and USDA compliant. All-welded construction measuring 15″ high × 18″ deep, gray powder-coated exterior with mill aluminum inlet screen and access panels. Net weight 189 lbs. Recommended for shipping \u0026amp; receiving doors, garage doors, cold storage, baggage doors, and conveyor lines. \u003cspan style=\"font-size: 0.875rem;\"\u003eSimple to install, operate, and maintain.\u003c\/span\u003e Made in U.S.A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-size: 0.875rem;\"\u003eSUPPORTING DOCUMENTS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Air-Curtain-Installation-Instructions-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eInstallation \u0026amp; Maintenance Instructions (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-Ambient-Air-Curtain-Data-Sheet.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eData Sheet (IDC12 Ambient)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-Air-Curtain-IDC12-IDC14-FLYER-1.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBrochure (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtain-Mounting-Options-including-Indirect-Gas-Heat.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Air Curtain Mounting Options\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Digital-Controls-for-Industrial-Air-Curtains-Flyer.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eBerner Digital Controls - Flyer\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Air-Curtains-with-Intelliswitch-Installation-Instructions.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Quick Start Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Intelliswitch-Navigation-Gen3c-D4-v4.15.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eIntelliswitch Gen3C Navigation Guide\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/Berner-Industrial-Direct-Drive-12-and-14-Replacement-Parts-Drawing.pdf?v=1764461379\" rel=\"noopener\" target=\"_blank\"\u003e \u003cstrong\u003eReplacement Parts List\/Diagram (IDC12\/14)\u003c\/strong\u003e \u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSINGLE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 120V, 208V, 240V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 120V, 208V, 240V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eTHREE PHASE AMBIENT* CONFIGURATIONS\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e36\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e42\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e48\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e60\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e72\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e78\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e84\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (2 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e96\" --- 208V, 240V, 480V, 600V (3 Motors)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e108\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e120\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e132\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e144\" --- 208V, 240V, 480V, 600V\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003e *Berner also manufactures the IDC12 Series with \u003cstrong\u003eElectric Heat\u003c\/strong\u003e, \u003cstrong\u003eSteam\/Hot Water Heat\u003c\/strong\u003e, and \u003cstrong\u003eIndirect Gas Heat Models\u003c\/strong\u003e, however these are currently not listed herein for sale. Please contact us if you're looking for more information, or visit \u003ca href=\"https:\/\/berner.com\" rel=\"noopener\" target=\"_blank\"\u003ewww.Berner.com\u003c\/a\u003e. \u003c\/em\u003e\u003c\/p\u003e\n\u003ch4 class=\"title\"\u003eAccessories\u003c\/h4\u003e\n\u003cp\u003eThis model requires a separate Activation Switch. All air curtains using control panels require an Activation Switch with the panel.\u003c\/p\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eControl Panels\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle phase control panel\u003c\/strong\u003e is required when a time delay is used, when a 24 volt control is used, and\/or when motor quantities exceed: (2) 1\/2 hp @ 120V or (3) 1\/2 hp @ 208–240V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree phase control panel (\u003ca href=\"https:\/\/aircurtainsdirect.com\/products\/9012cs40a3p208-24-single-phase-control-panel-nema-4-12-enclosure-208v-240v-for-1-to-3-motor-idc12-14-units\"\u003e9012CS40A3P208-24\u003c\/a\u003e)\u003c\/strong\u003e and activation switch are required for all three phase power supplies\u003c\/li\u003e\n\u003cli\u003eLocation of panel is factory installed on left hand end plate; optional right hand end plate or remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eElectrical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDoor Switches: roller, plunger, whisker arm, magnetic reed, heavy duty magnetic reed style\u003c\/li\u003e\n\u003cli\u003eHand\/Off\/Automatic switches\u003c\/li\u003e\n\u003cli\u003eDisconnect Switch(es) – toggle disconnects based on number of power supplies required\u003c\/li\u003e\n\u003cli\u003eRemote Thermostat \u0026amp; Locking Cover\u003c\/li\u003e\n\u003cli\u003eIndirect Gas Heater Transformer – remote mounted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Accessories\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWall support brackets\u003c\/li\u003e\n\u003cli\u003eExtension brackets\u003c\/li\u003e\n\u003cli\u003eFloor mounting brackets\u003c\/li\u003e\n\u003cli\u003eVertical tandem mounting bracket\u003c\/li\u003e\n\u003cli\u003e½” Washable filters\u003c\/li\u003e\n\u003cli\u003eNozzle extensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col wysiwyg\"\u003e\n\u003ch4\u003eBerner Intelliswitch\u003csup\u003eTM \u003c\/sup\u003e(Optional)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe Intelliswitch \u003cem\u003e(digital controller)\u003c\/em\u003e allows the user to program the air curtain to run for a set time in between door cycles, to operate on a schedule, and for air curtains with heat to run until the thermostat set point is satisfied \u003c\/li\u003e\n\u003cli\u003eSeveral pre-set programs to choose from or create a program tailored to the application\u003c\/li\u003e\n\u003cli\u003eControl panel is required when an Intelliswitch is used\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBerner AIR and Intelliswitch Package\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIncludes BACnet-IP Support\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor Industrial Air Curtains via Berner’s mobile app\u003c\/li\u003e\n\u003cli\u003eAccess reporting on energy \u0026amp; cost savings, door operations, and more\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDigital Controller\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTakes the place of Control Packages\u003c\/li\u003e\n\u003cli\u003eSimplified pre-set programs\u003c\/li\u003e\n\u003cli\u003eSingle speed motor operation\u003c\/li\u003e\n\u003cli\u003eLED clock display\u003c\/li\u003e\n\u003cli\u003eLow voltage circuit for unit activation\u003c\/li\u003e\n\u003cli\u003eSerial network connection available\u003c\/li\u003e\n\u003cli\u003eExternal thermostat provision\u003c\/li\u003e\n\u003cli\u003eCommercial grade components with operating range: 0° – 70°C or 32° – 158°F\u003c\/li\u003e\n\u003cli\u003eRoHS compliant\u003c\/li\u003e\n\u003cli\u003eTemperature probe (heated units only)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"page\" title=\"Page 1\"\u003e\n\u003cdiv class=\"layoutArea\"\u003e\n\u003cdiv class=\"column\"\u003e\n\u003ch4\u003eBerner AIR\u003csup\u003eTM \u003c\/sup\u003eSmart Controller \u0026amp; Berner App, includes BACnet\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRequires Intelliswitch\u003csup\u003eTM\u003c\/sup\u003e\n\u003c\/li\u003e\n\u003cli\u003eProgram, operate \u0026amp; monitor via smartphone \/ tablet\u003c\/li\u003e\n\u003cli\u003eBACnet-IP support\u003c\/li\u003e\n\u003cli\u003eRemote troubleshooting\u003c\/li\u003e\n\u003cli\u003eSecure: best practices for cyber security protocols followed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Berner","offers":[{"title":"Default Title","offer_id":48171984486641,"sku":"IDC12-2084AX","price":4700.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0663\/3452\/3633\/files\/IDC12AmbientAirCurtain-BernerIndustrialDirectDrive12Series.png?v=1764463153"}],"url":"https:\/\/aircurtainsdirect.com\/collections\/air-curtains-berner-idc12-industrial-direct-12-series.oembed","provider":"AirCurtainsDirect.com","version":"1.0","type":"link"}